Fault diagnosis
I12 TURN SIGNALS RH OR LH SIDE NOT WORKING
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
When the stalk switch is operated with the key ON, the turn signals do not work
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
| STEP | OPERATIONS TO BE CARRIED OUT | TEST RESULTS | ||
|---|---|---|---|---|
| 1 | INDIVIDUAL BULB CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check the condition of the bulbs and associated bulb holder; | Move on to Step | 1. Bulbs damaged | 1. Change bulbs | |
| 2. Light cluster fault | 2. Replace or change the light cluster | |||
| 2 | TURN SIGNAL ELECTRICAL CIRCUIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check the following, in order:
| Move on to Step | 1. Component defective | 1. 1. Replace defective component (in the case of a fuse, find out what caused it to blow). | |
| 2. Connections interrupted | 2. Repair the connections See E2020 DIRECTION INDICATORS / HAZARD WARNING LIGHTS | |||
| 3 | STEERING COLUMN SWITCH UNIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that an earth signal is present to the switch control unit when the stalk unit turn stalk switch is operated See E2020 DIRECTION INDICATORS / HAZARD WARNING LIGHTS | Move on to Step | Stalk unit not working properly | Replace the steering column switch unit Op. 5550A12 COMPLETE STALK UNIT - R+R FOR VERSIONS WITH AIR BAG | |
| 4 | SWITCH CONTROL UNIT CHECK | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
Check the following, in order:
| Move on to Step | 1. Power supplies/earths incorrect | 1. Restore correct power supplies/earths | |
| 2. Switch control unit fault | 2. Replace switch control unit Op. 5505A24 W/L AND SERVICE SWITCH MOUNT - R+R | |||
| 5 | CHECK ON CORRECT OPERATION | ALL OK | PROBLEMS ENCOUNTERED | ACTION |
| Check that the fault is no longer present | ||||