FIAT / DUCATO 244eLearn workshop manual · English · Offline edition
Fault diagnosis

K40 BATTERY CHARGING WARNING LIGHT NOT WORKING

Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
The warning light does not come on at key on.
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
STEPOPERATIONS TO BE CARRIED OUTTEST RESULTS
1CONTINUITY CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check the continuity of the connections between alternator and instrument panel and control panel warning light internal circuit continuity See E4010 INSTRUMENT PANELMove on to Step1. Connections not correct1. Restore the connections See E4010 INSTRUMENT PANEL
2. Instrument panel defective2. Replace instrument panel Op. 5560B10 ANALOGUE CONTROL PANEL - R+R
2ALTERNATOR CHECKALL OKPROBLEMS ENCOUNTEREDACTION
Check alternator earth signal See E4010 INSTRUMENT PANELMove on to StepAlternator defectiveService or replace the alternator
3CHECK ON CORRECT OPERATIONALL OKPROBLEMS ENCOUNTEREDACTION
Check that the fault is no longer present