FIAT / DUCATO 244eLearn workshop manual · English · Offline edition
Procedures

1042A24 CNG SYSTEM SINGLE-ACTING VALVE - R.& R.

Engines: 2.0 16V
Engines: 2.0 16V

RemovingManual illustration 20

RefittingManual illustration 21
Position the vehicle on the lift.Proceed with draining the high pressure circuit following the instructions in the specific operation:Op. 1042A02 METHANE SYSTEM SAFETY SET UP1. Undo the CNG repressurizing pipe connector.2. Undo the single-acting valve and remove it.
Manual illustration 244006719
Engines: 2.0 16V

RefittingManual illustration 21

RemovingManual illustration 20
Fit the single-acting valve and tigthen it to the three-way connector.
[symbol: coppie.tif]Value daNmFasteningComponentØ  
-2.8Connector--
Tighten the connector for the CNG repressurizing pipe to the single-acting valve.
[symbol: coppie.tif]Value daNmFasteningComponentØ  
-2.8Connector--
Move the CNG cut-off solenoids to open position by hand and check system is efficient.Remove the vehicle from the lift.