Procedures
1042A46 CNG RECHARGING SYSTEM 3-WAY FITTING (1)-R R
Engines: 2.0 16V
Removing
Position the vehicle on the lift.Proceed with draining the high pressure circuit following the instructions in the specific operation:Op. 1042A02 METHANE SYSTEM SAFETY SET UP1. Undo the connector for the pressure reduction unit supply pipe.2. Undo the connector for the canister pipe.3. Undo the connector (3a) and the single-acting valve (3b).4. Remove the CNG system three-way connector.
Engines: 2.0 16V
Refitting
Fit the CNG system three-way connector.Tighten the single-acting valve and the connector. Tighten the connector for the CNG canisters.| [symbol: coppie.tif] | Value daNm | Fastening | Component | Ø |
|---|---|---|---|---|
| - | 2.8 | Connector | - | - |
| [symbol: coppie.tif] | Value daNm | Fastening | Component | Ø |
|---|---|---|---|---|
| - | 2.8 | Connector | - | - |