FIAT / DUCATO 244eLearn workshop manual · English · Offline edition
Procedures

1042A46 CNG RECHARGING SYSTEM 3-WAY FITTING (1)-R R

Engines: 2.0 16V
Engines: 2.0 16V

RemovingManual illustration 20

RefittingManual illustration 21
Position the vehicle on the lift.Proceed with draining the high pressure circuit following the instructions in the specific operation:Op. 1042A02 METHANE SYSTEM SAFETY SET UP1. Undo the connector for the pressure reduction unit supply pipe.2. Undo the connector for the canister pipe.3. Undo the connector (3a) and the single-acting valve (3b).4. Remove the CNG system three-way connector.
Manual illustration 244006740
Engines: 2.0 16V

RefittingManual illustration 21

RemovingManual illustration 20
Fit the CNG system three-way connector.Tighten the single-acting valve and the connector. Tighten the connector for the CNG canisters.
[symbol: coppie.tif]Value daNmFasteningComponentØ  
-2.8Connector--
Tighten the connector for the pipe to the pressure reduction unit.
[symbol: coppie.tif]Value daNmFasteningComponentØ  
-2.8Connector--
Move the CNG cut-off solenoids to open position by hand and check system is efficient.Remove the vehicle from the lift.