Procedures
1048A31 RIGID PIPE CONNECTING AIR CLEANER TO INLET MANIFOLD RIGID PIPE R R
Engines: 2.0 16V
Removing
1. Remove the fastening bands (1a) and undo the fixing nuts on the tappet cover (1b) and remove the rigid pipe (1c).
Engines: 2.0 16V
Refitting
- Place the rigid pipe in position and renew the fastening bands.- Tighten the nuts fixing the rigid pipe to the tappet cover.