FIAT / DUCATO 244eLearn workshop manual · English · Offline edition
Procedures

1048A39 SLEEVE FROM AIR CLEANER TO RIGID PIPE - R R

Engines: 2.0 16V
Engines: 2.0 16V

RemovingManual illustration 20

RefittingManual illustration 21
1. Open the hose retaining bands.2. Release the hose from the air filter casing and from the rigid pipe and remove it.
Manual illustration 244002725
Engines: 2.0 16V

RefittingManual illustration 21

RemovingManual illustration 20
- Fit the hose on the air filter casing and on the rigid pipe and restore the fastening bands.