- Disconnect the negative battery terminal.- Raise the vehicle on the lift.- Position a suitable container for collecting the fuel.1. Disconnect the pipe from the coupling with the fuel supply pipe from the pump loosening the retaining band.
1. Disconnect the fuel inlet pipe from the independent heater loosening the retaining band.- Remove the fuel supply pipe to the additional independent heater.
- Connect the fuel supply pipe to the independent heater unit using the retaining band.- Fasten the support for the independent heater unit to the bodyshell tightening the nuts and bolts to the recommended torque.
Value - daNm
Fastening
Component
Ø
Validity
2
Nut
ADDITIONAL HEATER BOILER
M8
T.T
Value - daNm
Fastening
Component
Ø
Validity
2
Bolt
ADDITIONAL HEATER BOILER
M8
T.T
- Connect the pipe to the coupling with the fuel supply pipe from the pump using the retaining band.- Lower the vehicle on the lift.- Connect the negative battery terminal.