FIAT / DUCATO 244eLearn workshop manual · English · Offline edition
Procedures

5020M80 WATER PUMP FOR ADDITIONAL HETAER UNIT - R.R.

Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V

RemovingManual illustration 20

RefittingManual illustration 21
- Disconnect the negative battery terminal. Op. 5020M10 INDEPENDENT HEATER UNIT - R R1. At the bench, undo the bolts (1a) fixing the water pump bracket (1b).- Remove the band fastening the flexible pipe to the pump.2. Remove the water pump.
Manual illustration 244004208
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V

RefittingManual illustration 21

RemovingManual illustration 20
- Place the water pump in the correct fitting position.- Fit the flexible pipe on the pump and secure it using the retaining band.- Fasten the water pump to the independent heater casing tightening the bolt fixing the pump retaining band.- Connect the negative battery terminal. Op. 0010T20 COOLANT CHECK DENSITY AND TOP UP IF NECESSARY