5020M86 FAN FOR ADDITIONAL HEATER UNIT - R.R.

Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V

RemovingManual illustration 20

RefittingManual illustration 21
- Disconnect the negative battery terminal. Op. 5020M10 INDEPENDENT HEATER UNIT - R R1. At the bench, disconnect the inlet pipe loosening the retaining bands.
Manual illustration 244004213
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
1. Remove the electrical connection protective cover.2. Disconnect the electrical connectors.
Manual illustration 244004214
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
1. Undo the bolts (1a) fixing the water pump bracket (1b).- Remove the band fastening the flexible pipe to the pump.2. Remove the water pump.
Manual illustration 244004215
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
1. Undo the bolts fixing the fan assembly.2. Remove the fan assembly.
Manual illustration 244004216
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V

RefittingManual illustration 21

RemovingManual illustration 20
- Fasten the fan assembly to the independent heater casing tightening the fixing bolts.- Place the water pump in the correct fitting position.- Fit the flexible pipe on the pump and secure it using the retaining band.- Fasten the water pump to the independent heater casing tightening the bolt fixing the pump retaining band.- Connect the electrical connectors and secure the protective cover.- Fasten the air inlet pipe to the heater using the retaining bands. Op. 5020M10 INDEPENDENT HEATER UNIT - R R- Connect the negative battery terminal. Op. 0010T20 COOLANT CHECK DENSITY AND TOP UP IF NECESSARY