FIAT / DUCATO 244eLearn workshop manual · English · Offline edition
Procedures

5040C60 AIR CONDITIONING EVAPORATING UNIT - R.R.

Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
Equipment / version codes: Supplementary air conditioner [B42]

RemovingManual illustration 20

RefittingManual illustration 21
- Disconnect the negative battery terminal. Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE Op. 5010B65 EVAPORATOR/CONVEYOR UNIT MIDDLE LINING on the roof panel - R.R. Op. 5010B61 EVAPORATOR/CONVEYOR UNIT SIDE LINING on the roof panel, left or right (one) - R.R.Left side1. Undo bolt (1a) and disconnect pipe (1b) from expansion valve to compressor and (1c) from bulkhead coupling to expansion valve (1d).2. Open the band (2a) and remove the condensate drain pipe (2b).3. Open the band (3a) and remove the condensate drain pipe (3b).4. Disconnect the electrical connections and release the wiring from the evaporator mount.5. Place an appropriate support tool under the evaporator.6. Drill out the retaining rivets.7. Remove the evaporator.
Manual illustration 244004308
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
Equipment / version codes: Supplementary air conditioner [B42]

RefittingManual illustration 21

RemovingManual illustration 20
- Fit the evaporator in its seat and secure with rivets.- Remove the tool supporting the air conditioner evaporator.- Connect the electrical connections and renew the fastening bands.- Connect the condensate drain pipes and renew the retaining collars.- Connect the pipes to the expansion valve and tighten the bolt. Op. 5010B61 EVAPORATOR/CONVEYOR UNIT SIDE LINING on the roof panel, left or right (one) - R.R.Left side Op. 5010B65 EVAPORATOR/CONVEYOR UNIT MIDDLE LINING on the roof panel - R.R. Op. 0010T84 COOLANT FOR AIR CONDITIONING SYSTEM DEHYDRATE AND RECHARGE- Disconnect the negative battery terminal.