FIAT / DUCATO 244eLearn workshop manual · English · Offline edition
Procedures

5040C93 LH VENTILATION DISTRIBUTION FLAP RR WITH AIR CONDITIONER BOX REMOVED

Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V

RemovingManual illustration 20

RefittingManual illustration 21
1. Undo the fixing bolts.2. Remove the recirculation air intake duct.
Manual illustration 244004318
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
1. Undo the fixing bolts.2. Remove the rear guard.3. Undo the fixing bolt.4. Remove the side guard.
Manual illustration 244004319
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
1. Remove the retaining band.2. Disconnect the radiator return pipe from the tap and place it at the side.3. Open the fastening spring.4. Disconnect the control cable and remove it.
Manual illustration 244004320
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
1. Undo the fixing bolt.2. Remove the flap linkage control device.
Manual illustration 244004321
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
1. Disconnect the ball joint.2. Undo the fixing bolt.3. Remove the floor air distribution flap linkage.
Manual illustration 244004322
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
1. Act on the springs (1a) and remove the linkage (1b).
Manual illustration 244004323
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V
- Remove the upper seal using a suitable tool.1. Undo the upper bolt fixing the tap.2. Undo the fixing bolts.3. Remove the metal springs.4. Remove the front upper half casing.5. Remove the flaps.
Manual illustration 244004324
Engines: 2.0 16V, 2.0 JTD 8V, 2.3 JTD 16V, 2.8 JTD 8V

RefittingManual illustration 21

RemovingManual illustration 20
- Position the flaps inside the half casings.- Tighten the fixing bolts.- Attach the metal springs.- Tighten the upper bolt fixing the tap.- Fit a new upper seal.- Position the flap linkage and secure it.- Position the floor air distribution flap linkage and tighten the fixing bolt.- Connect the ball joint to the floor air distribution flap.- Position the flap linkage control device and tighten the fixing bolt.- Connect the return pipe from the radiator to the tap and secure it using a suitable band.- Connect the control cable and secure it using the fastening spring.- Position the side guard and tighten the fixing bolt.- Position the rear guard and tighten the fixing bolts.- Position the recirculation air intake duct and tighten the fixing bolts.