Drain the return pipe from the injectors to the return solenoid valve, following the instructions in the procedure:Op. 1043A02 LPG SYSTEM LINES PIPE DRAINING OPERATIONSDisconnect the negative battery terminal.1. Undo the nuts (1a) and move the engine coolant reservoir (1a) away from the work area, leaving the pipes connected.
Engines: 2.0 16V
1. Undo the connector for the flexible return pipe from the injectors on the intermediate block.Loosen the connectors for the rigid return pipe on the solenoid valve and on the intermediate block.2. Undo the nuts fixing the intermediate connector to the mounting bracket.3. Undo the connector (3a) for the rigid return pipe; then remove the intermediate block (3b).
Position the intermediate block and secure it to the mounting bracket without tightening the retaining nuts.Tighten the connector for the rigid return pipe to the intermediate block.
[symbol: coppie.tif]
Value daNm
Fastening
Component
Ø
-
2.5
Connector
on the intermediate block
M12 X 1
Tighten the connector for the rigid return pipe to the solenoid valve to torque.
[symbol: coppie.tif]
Value daNm
Fastening
Component
Ø
-
1.5
Connector
on the return solenoid valve
M10 X 1
Tighten the nuts fixing the intermediate block to the mounting bracket to torque.
[symbol: coppie.tif]
Value daNm
Fastening
Component
Ø
-
0.9
Nut
to the mounting bracket
M6
Tighten the connector for the flexible return pipe from the injectors to the recommended torque.